

Accurate an Non-Invasive
RESMON PRO FULL utilizes oscillometry (also known as forced oscillation technique or FOT) to accurately and non-invasively measure the mechanical properties of the respiratory system using just a few normal tidal breaths.
This advanced technology offers a simple and effort-independent method to detect and localize airway obstruction, allowing differentiation between peripheral, central, or heterogeneous types.
Versatility for All Patients
The versatility of RESMON PRO FULL extends to a variety of testing environments, from pulmonary laboratories to bedside assessments, private offices, and sites for clinical trials or research studies.
Whether dealing with COPD, adult and pediatric asthma, or assessing the effectiveness of airway clearance techniques in physiotherapy, RESMON PRO FULL is the go-to solution for physicians seeking better diagnosis and staying on the cutting edge of innovation.
The RESMON CART (REF.: RT1106), a medical cart specifically optimized for RESMON PRO FULL, enhances the portability of the device, enabling easy transport and facilitating testing at the bedside or in the lab.

Advanced Features for Enhanced Performance
RESMON PRO FULL is equipped with advanced calculation algorithms based on the latest scientific research and clinical findings, ensuring exceptional performance.
By integrating respiratory physiology with state-of-the-art technology, RESMON PRO FULL introduces a range of new advanced parameters that combine oscillometry and static lung volume measurements, such as closing volume (CVfot), critical reactance (Xcrit), and oscillometric airway conductance (sGrs). This comprehensive set of measurements enhances the physician’s ability to detect diseases, even in their earliest stages, and effectively monitor the impact of therapeutic interventions on disease progression.

Dynamic “Within-Breath” Testing
Real-time display of resistance (Rrs), reactance (Xrs) and flow or volume (user selectable)
• Measurement of inspiratory, expiratory and total Rrs and Xrs parameters
• Spectral analysis with the calculation of R5-19, AX and Fres
• Automatic detection and quantification of tidal expiratory flow limitation (EFLt) with ΔXrs index graph and % of flow limited breaths (FL%), (patent nr. wo2003103493)
• Full respiratory pattern measurement and reporting of VE, VT, RR, Ti/Ttot, Vt/Ti, Vt/Te
• Customizable tidal loops graphs (available signals: Flow, Volume, Resistance, Reactance and Impedance)
Slow Vital Capacity Testing
• SVC for monitoring of restrictive patterns
• IC for hyperinflation detection, pre-post testing for evaluating effect treatment
• Closing volume (CVfot) and critical reactance (Xcrit) for the evaluation of de-recruitment of peripheral airways
• Specific airway conductance (sGrs) for the evaluation of therapeutic intervention compensated for changes in lung volumes
Three Measurement Modes
• Enhanced and optimized multi-frequency mode of 5-11-19 Hz, from children to adults
• Single-frequency mode options of 5, 6, 8, 10 Hz (for children, severely obstructed patients and special research purposes)
• Enhanced and optimized Pseudo Random Noise (PSN) of 5-37 Hz
Enhanced Comfort and Testing Efficiency
• Automatic adjustment of stimulus amplitude based on patient impedance to maximize measurement quality and optimal patient comfort
• Efficient testing with automatic discard of breaths affected by artifacts (i.e. cough, glottis closure, etc) and choice of number of accepted breaths, or time to end the test automatically, minimizing operator intervention
• CoV % (coefficient of variability) within-measurement and within-session with color coded warning, for optimal quality control
• Operator accessible screen, post-test, to review and edit breaths to include into the calculation of the results
• User selectable sets of reference equations for predicted normal value and Z-score calculation
Convenient Size and Functions
• Self-contained and compact unit with data transfer capability on USB memory stick, directly to PCs via USB-OTG or LAN cable
• Connectivity options, USB and HDMI ports, with external keyboard, mouse, screen or projector
• Active-wash fan for expired CO2 removal from the system reducing system dead space to 35 mL
• Unique impedance verification tube included, to daily check the accuracy of both resistance (Rrs) and reactance (Xrs)
• Wide 10.1’’ color touchscreen for fast, easy and intuitive test management
• Built-in database to store, retrieve, edit or delete patient data
• Multi-user access with password protected data security
• Detailed report of results for trending, analysis and statistics. Data available in raw format, XSL/CSV and PDF output as well as export to external PC (via USB-OTG or LAN cable for safe transfer connection and data protection)
Pre-Post Results

Technical Specifications
